Aim: To determine the accuracy of cervical elastography in predicting labor induction success. Materials and methods: A systematic search, review, and meta-analysis of observational studies published in English language between January 2000 and October 2014 was performed. It included studies considering cervix sonoelastography as the index test and successful labor or vaginal delivery as the reference standard. As cervix length and Bishop score were considered comparator tests, the quality of the included studies was assessed using quality assessment tool for diagnostic accuracy studies (QUADAS) tool. Results: A total of four studies assessing 323 women before medical induction of labor were included. Cervical elastography, cervical length, and Bishop score showed a diagnostic odds ratio (DOR) with 95% confidence interval (CI) for successful labor prediction of 3.50 (1.93–6.35), 3.35 (1.94–5.77), and 1.45 (0.33–6.41), respectively. In addition, cervical elastography, cervical length, and Bishop score showed a DOR with 95% CI for successful vaginal delivery prediction of 5.24 (3.23–8.50), 4.94 (2.72–8.98), and 4.62 (0.69–30.94), respectively. Considering the summary of receiver operating characteristic curves we show that cervical elastography or length are similarly reliable, and both are more reliable to predict successful labor than the Bishop score. Two studies were excluded because it was not possible to retrieve data for the meta-analysis. Among the excluded studies, one found no significant contribution from elastography for prediction of successful labor induction. Conclusions: Even though there is a limited number of studies included and the heterogeneity of the methods used, cervical elastography seems to be a promising tool for predicting successful labor induction and vaginal delivery in women treated by medical induction of labor

Diagnostic accuracy of cervical elastography in predicting labor induction success: a systematic review and meta-analysis.

LONDERO, Ambrogio P.;BERTOZZI, Serena;DRIUL, Lorenza;FRUSCALZO, Arrigo
2015-01-01

Abstract

Aim: To determine the accuracy of cervical elastography in predicting labor induction success. Materials and methods: A systematic search, review, and meta-analysis of observational studies published in English language between January 2000 and October 2014 was performed. It included studies considering cervix sonoelastography as the index test and successful labor or vaginal delivery as the reference standard. As cervix length and Bishop score were considered comparator tests, the quality of the included studies was assessed using quality assessment tool for diagnostic accuracy studies (QUADAS) tool. Results: A total of four studies assessing 323 women before medical induction of labor were included. Cervical elastography, cervical length, and Bishop score showed a diagnostic odds ratio (DOR) with 95% confidence interval (CI) for successful labor prediction of 3.50 (1.93–6.35), 3.35 (1.94–5.77), and 1.45 (0.33–6.41), respectively. In addition, cervical elastography, cervical length, and Bishop score showed a DOR with 95% CI for successful vaginal delivery prediction of 5.24 (3.23–8.50), 4.94 (2.72–8.98), and 4.62 (0.69–30.94), respectively. Considering the summary of receiver operating characteristic curves we show that cervical elastography or length are similarly reliable, and both are more reliable to predict successful labor than the Bishop score. Two studies were excluded because it was not possible to retrieve data for the meta-analysis. Among the excluded studies, one found no significant contribution from elastography for prediction of successful labor induction. Conclusions: Even though there is a limited number of studies included and the heterogeneity of the methods used, cervical elastography seems to be a promising tool for predicting successful labor induction and vaginal delivery in women treated by medical induction of labor
File in questo prodotto:
File Dimensione Formato  
Londero2015_jpm-2015-0035.pdf

non disponibili

Descrizione: review
Tipologia: Documento in Post-print
Licenza: Non pubblico
Dimensione 641.4 kB
Formato Adobe PDF
641.4 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1092219
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 37
social impact