Portland cement pastes prepared at various water/cement ratios were studied using the rate-controlled coaxial cylinder viscometer Rotovisko-Haake 20, system M5-oscillatory measuring device MV2P with serrated surfaces. The tests were performed under both continuous and oscillatory flow conditions. In this article, experimental shear stress and shear rate data were fitted very satisfactorily with a model proposed by the authors. Excellent results were achieved also by applying the Quemada equation. Oscillatory flow data gave further information on the workability of the pastes investigated. In addition, the influence of two different commercial superplasticizing agents (Concretan RX and Ergomix 1000, the first based on polycyclic copolymers with modified structures carrying hydroxylated side chains, the second on a modified polyacrylic resin) was studied with the aim of determining their optimum dosage. In the case of Ergomix 1000, agreement between the optimum dosage determined rheologically and that recommended by the producer was obtained.

FLOW BEHAVIOR OF FRESH PORTLAND CEMENT PASTES

PAPO, Adriano;
2004-01-01

Abstract

Portland cement pastes prepared at various water/cement ratios were studied using the rate-controlled coaxial cylinder viscometer Rotovisko-Haake 20, system M5-oscillatory measuring device MV2P with serrated surfaces. The tests were performed under both continuous and oscillatory flow conditions. In this article, experimental shear stress and shear rate data were fitted very satisfactorily with a model proposed by the authors. Excellent results were achieved also by applying the Quemada equation. Oscillatory flow data gave further information on the workability of the pastes investigated. In addition, the influence of two different commercial superplasticizing agents (Concretan RX and Ergomix 1000, the first based on polycyclic copolymers with modified structures carrying hydroxylated side chains, the second on a modified polyacrylic resin) was studied with the aim of determining their optimum dosage. In the case of Ergomix 1000, agreement between the optimum dosage determined rheologically and that recommended by the producer was obtained.
File in questo prodotto:
File Dimensione Formato  
PartSciTech22_001.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 615.78 kB
Formato Adobe PDF
615.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/694590
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 13
social impact