Abstract: Purpose: To evaluate the effectiveness of ab-interno microcatheterization and 360◦ viscodi- lation of Schlemm’s canal (SC) performed with OMNI viscosurgical system in open angle glaucoma (OAG) together or not with phacoemulsification. Setting: Two surgical sites. Design: Retrospective, observational. Methods: Eighty eyes from 73 patients with mild to moderate OAG underwent ab- interno SC viscodilation performed with OMNI system. Fifty eyes (Group 1) underwent only SC viscodilation, while 30 eyes (Group 2) underwent glaucoma surgery + cataract extraction. Primary success endpoint at 12 months was an intraocular pressure (IOP) reduction higher than 25% from baseline with an absolute value of 18 mmHg or lower, either on the same number or fewer ocular hypotensive medications, without further interventions. Secondary effectiveness endpoints included mean IOP, number of medications and comparison of outcomes between groups. Safety endpoints consisted of best-corrected visual acuity (BCVA), adverse events (AEs), and subsequent surgical procedures. Results: Primary success was achieved in 40.0% and 67.9% in Groups 1 and 2, respec- tively. Mean IOP at 12-month follow-up showed a significant reduction in both groups (from 23.0 to 15.6 mmHg, p < 0.001, and from 21.5 to 14.1, p < 0.001, in Groups 1 and 2, respectively). Mean medication number decreased in both groups (from 3.0 to 2.0, p < 0.001 and from 3.4 to 1.9, p < 0.001, in Groups 1 and 2, respectively). AEs included hyphema (2 eyes), mild hypotony (4 eyes), IOP spikes one month after surgery (1 eye). Twelve eyes (15.0%) required subsequent surgical procedures. No BCVA reduction was observed. Conclusions: Viscodilation of SC using OMNI viscosurgical systems is safe and relatively effective in reducing IOP in adult patients with OAG.
360 ̋ Ab-Interno Schlemm’s Canal Viscodilation with OMNI Viscosurgical Systems for Open-Angle Glaucoma—Midterm Results
Giacomo ToneattoInvestigation
;Marco Zeppieri
Supervision
;Veronica Papa;Laura Rizzi;Andrea Gabai;
2022-01-01
Abstract
Abstract: Purpose: To evaluate the effectiveness of ab-interno microcatheterization and 360◦ viscodi- lation of Schlemm’s canal (SC) performed with OMNI viscosurgical system in open angle glaucoma (OAG) together or not with phacoemulsification. Setting: Two surgical sites. Design: Retrospective, observational. Methods: Eighty eyes from 73 patients with mild to moderate OAG underwent ab- interno SC viscodilation performed with OMNI system. Fifty eyes (Group 1) underwent only SC viscodilation, while 30 eyes (Group 2) underwent glaucoma surgery + cataract extraction. Primary success endpoint at 12 months was an intraocular pressure (IOP) reduction higher than 25% from baseline with an absolute value of 18 mmHg or lower, either on the same number or fewer ocular hypotensive medications, without further interventions. Secondary effectiveness endpoints included mean IOP, number of medications and comparison of outcomes between groups. Safety endpoints consisted of best-corrected visual acuity (BCVA), adverse events (AEs), and subsequent surgical procedures. Results: Primary success was achieved in 40.0% and 67.9% in Groups 1 and 2, respec- tively. Mean IOP at 12-month follow-up showed a significant reduction in both groups (from 23.0 to 15.6 mmHg, p < 0.001, and from 21.5 to 14.1, p < 0.001, in Groups 1 and 2, respectively). Mean medication number decreased in both groups (from 3.0 to 2.0, p < 0.001 and from 3.4 to 1.9, p < 0.001, in Groups 1 and 2, respectively). AEs included hyphema (2 eyes), mild hypotony (4 eyes), IOP spikes one month after surgery (1 eye). Twelve eyes (15.0%) required subsequent surgical procedures. No BCVA reduction was observed. Conclusions: Viscodilation of SC using OMNI viscosurgical systems is safe and relatively effective in reducing IOP in adult patients with OAG.File | Dimensione | Formato | |
---|---|---|---|
6013.pdf
accesso aperto
Tipologia:
Altro materiale allegato
Licenza:
Creative commons
Dimensione
1.81 MB
Formato
Adobe PDF
|
1.81 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.