In Band Full Duplexing (IBFD) has recently become attractive for power line communications (PLC). In this paper we analyze the role of the first stage of a PLC-IBFD modem: The hybrid coupler. An analytical analysis of its influence on the signal transfer function is performed and some simulations using a measurement database are also included. Possible hardware implementation of a PLC hybrid coupler are finally discussed.
In Band Full Duplex PLC: The role of the hybrid coupler
Tonello A. M.
2016-01-01
Abstract
In Band Full Duplexing (IBFD) has recently become attractive for power line communications (PLC). In this paper we analyze the role of the first stage of a PLC-IBFD modem: The hybrid coupler. An analytical analysis of its influence on the signal transfer function is performed and some simulations using a measurement database are also included. Possible hardware implementation of a PLC hybrid coupler are finally discussed.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.