A study concerning the evaluation of seismic response of statues exhibited in art museums, and a base-isolated floor strategy for their enhanced protection, are presented in this paper. Attention is particularly focused on statues made of small tensile strength materials, whose behaviour is simulated by a smeared-crack finite element approach. Seismic performance is assessed by referring to four levels specially postulated herein, and namely: 1) Rest conditions; 2) No rocking; 3) Damage control; and 4) Collapse prevention. The response is investigated via incremental dynamic analysis, by progressively increasing the amplitude of the ground motion histories adopted as inputs, and by relating output data to the limit conditions fixed for the above-mentioned performance levels. The assessment procedure is applied to a demonstrative case study, represented by a marble statue to be exhibited in the museum wing situated at the ground level of a medieval castle in Italy, according to an architectural hypothesis of partial rebuilding and reuse of the stronghold. The design solution for the base-isolated floor consists in a system of double-friction pendulum isolators. The finite element model constitutive laws and parameters, the dynamic analyses carried out in fixed-base and base-isolated floor conditions, and the practical implementation of the assumed performance assessment criteria are reported for the statue examined, along with a selection of technical details of the floor design.

Performance analysis of seismically excited statues in fixed-base and base-isolated conditions

Sorace Stefano
;
2015-01-01

Abstract

A study concerning the evaluation of seismic response of statues exhibited in art museums, and a base-isolated floor strategy for their enhanced protection, are presented in this paper. Attention is particularly focused on statues made of small tensile strength materials, whose behaviour is simulated by a smeared-crack finite element approach. Seismic performance is assessed by referring to four levels specially postulated herein, and namely: 1) Rest conditions; 2) No rocking; 3) Damage control; and 4) Collapse prevention. The response is investigated via incremental dynamic analysis, by progressively increasing the amplitude of the ground motion histories adopted as inputs, and by relating output data to the limit conditions fixed for the above-mentioned performance levels. The assessment procedure is applied to a demonstrative case study, represented by a marble statue to be exhibited in the museum wing situated at the ground level of a medieval castle in Italy, according to an architectural hypothesis of partial rebuilding and reuse of the stronghold. The design solution for the base-isolated floor consists in a system of double-friction pendulum isolators. The finite element model constitutive laws and parameters, the dynamic analyses carried out in fixed-base and base-isolated floor conditions, and the practical implementation of the assumed performance assessment criteria are reported for the statue examined, along with a selection of technical details of the floor design.
2015
9781510810211
File in questo prodotto:
File Dimensione Formato  
693.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Non pubblico
Dimensione 634.38 kB
Formato Adobe PDF
634.38 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1269965
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact