Linear sweep voltammetry (LSV) and cyclic voltammetry (CV) are the most widely used voltammetric techniques for studying redox reactions of both organic and inorganic compounds because they are unmatched in their ability to provide information on the steps involved in electrochemical processes with only a modest expenditure of time and effort in the acquisition and interpretation of data. These electroanalytical methods require simple and inexpensive instrumentation and provide not only information on the electrochemical quantities typical of a redox process, but also allow investigations of chemical reactions coupled with charge transfer steps. This is because the electrode can be used as a tool for producing reactive species in a small solution layer surrounding its surface and at the same time to monitor chemical reactions involving these species. Moreover, since the relevant responses can be obtained within a few milliseconds after stimulation of the electrode, they may be used for studying mechanisms involving very fast reactions, thus allowing detection of short�lived transient intermediates. LSV and CV techniques were proposed at the beginning of the 1950s and in those years some theoretical approaches able to rationalize the simplest responses were worked out. However, the use of these electroanalytical methods has received considerable impetus only more recently thanks to increased knowledge of more subtle criteria for interpreting the relevant responses and to greater availability of theoretical tools for processing experimental data. This article will briefly survey the analytical performance of these techniques, as well as the criteria followed to gain information regarding participants in electrochemical processes from the recorded responses.

Voltammetry - Linear sweep and cyclic

BONTEMPELLI, Gino;TONIOLO, Rosanna
2005-01-01

Abstract

Linear sweep voltammetry (LSV) and cyclic voltammetry (CV) are the most widely used voltammetric techniques for studying redox reactions of both organic and inorganic compounds because they are unmatched in their ability to provide information on the steps involved in electrochemical processes with only a modest expenditure of time and effort in the acquisition and interpretation of data. These electroanalytical methods require simple and inexpensive instrumentation and provide not only information on the electrochemical quantities typical of a redox process, but also allow investigations of chemical reactions coupled with charge transfer steps. This is because the electrode can be used as a tool for producing reactive species in a small solution layer surrounding its surface and at the same time to monitor chemical reactions involving these species. Moreover, since the relevant responses can be obtained within a few milliseconds after stimulation of the electrode, they may be used for studying mechanisms involving very fast reactions, thus allowing detection of short�lived transient intermediates. LSV and CV techniques were proposed at the beginning of the 1950s and in those years some theoretical approaches able to rationalize the simplest responses were worked out. However, the use of these electroanalytical methods has received considerable impetus only more recently thanks to increased knowledge of more subtle criteria for interpreting the relevant responses and to greater availability of theoretical tools for processing experimental data. This article will briefly survey the analytical performance of these techniques, as well as the criteria followed to gain information regarding participants in electrochemical processes from the recorded responses.
2005
0127641009
File in questo prodotto:
File Dimensione Formato  
Encyclopedia2.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 598.03 kB
Formato Adobe PDF
598.03 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/850815
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact