Pounding is one of the greatest sources of seismic vulnerability of pre-normative R/C structures, as they have often been built at poor distance from adjacent buildings. The effects of pounding can be particularly severe in slender modern R/C heritage structures, including civic or bell towers. An emblematic case study falling in this class of structures, i.e. a monumental R/C bell tower constructed in the early 1960s to replace the former 19th century tower of the Chiesa del Sacro Cuore in Florence, is analyzed in this paper. In order to assess the effects of pounding, a non-linear dynamic finite element enquiry was carried out by simulating collisions with a multi-link viscoelastic contact model originally implemented in this study. The survey results show that pounding affects the seismic response of the bell tower and the church as early as an input seismic action scaled at the amplitude of the normative basic design earthquake level. A retrofit hypothesis to prevent pounding is then proposed, which consists in linking the two structures by means of a pair of fluid-viscous dampers. The technical implementation of this rehabilitation strategy and the benefits induced in the response of the bell tower are discussed in detail in the paper. © 2013 WIT Press.

Seismic pounding mitigation of a modern heritage R/C bell tower

SORACE, Stefano;
2013-01-01

Abstract

Pounding is one of the greatest sources of seismic vulnerability of pre-normative R/C structures, as they have often been built at poor distance from adjacent buildings. The effects of pounding can be particularly severe in slender modern R/C heritage structures, including civic or bell towers. An emblematic case study falling in this class of structures, i.e. a monumental R/C bell tower constructed in the early 1960s to replace the former 19th century tower of the Chiesa del Sacro Cuore in Florence, is analyzed in this paper. In order to assess the effects of pounding, a non-linear dynamic finite element enquiry was carried out by simulating collisions with a multi-link viscoelastic contact model originally implemented in this study. The survey results show that pounding affects the seismic response of the bell tower and the church as early as an input seismic action scaled at the amplitude of the normative basic design earthquake level. A retrofit hypothesis to prevent pounding is then proposed, which consists in linking the two structures by means of a pair of fluid-viscous dampers. The technical implementation of this rehabilitation strategy and the benefits induced in the response of the bell tower are discussed in detail in the paper. © 2013 WIT Press.
2013
9781845647308
File in questo prodotto:
File Dimensione Formato  
STREMAH 2013_Pratesi-Sorace-Terenzi_sc.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 2.1 MB
Formato Adobe PDF
2.1 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/872724
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact