This paper presents the use of a statistical approach to estimate physical/electrochemical parameters of impedance spectroscopy experiments performed with a realistic nanoelectrodes array biosensor platform. The Bayesian estimation methodology is based on the combination of nanobiosensor simulations, performed with the ENBIOS tool, with Markov-Chain Monte Carlo (MCMC) analyses. A simple 1D electrode-electrolyte geometry is first considered as a validation test case, allowing the accurate estimation of Stern layer permittivity and salt concentration, as set by a reference analytical model. Then, full 3D analyses of the nanoelectrodes’ array system are performed in order to estimate a number of relevant parameters for measurements in electrolyte. Furthermore, moving to more challenging test cases, size/permittivity of microparticles suspended in electrolyte will also be discussed. This methodology allows for the determination of impedance spectroscopy data parameters, and quantification of parameter uncertainties in these multi-variable detection problems. It is thus a very promising approach in order to improve the precision of biosensor measurement predictions, which are intrinsically affected by many parameters.
Calibration, Compensation, Parameter Estimation, and Uncertainty Quantification for Nanoelectrode Array Biosensors
Andrea Cossettini;Paolo Scarbolo;Naseer Muhammad;Luca Selmi
2018-01-01
Abstract
This paper presents the use of a statistical approach to estimate physical/electrochemical parameters of impedance spectroscopy experiments performed with a realistic nanoelectrodes array biosensor platform. The Bayesian estimation methodology is based on the combination of nanobiosensor simulations, performed with the ENBIOS tool, with Markov-Chain Monte Carlo (MCMC) analyses. A simple 1D electrode-electrolyte geometry is first considered as a validation test case, allowing the accurate estimation of Stern layer permittivity and salt concentration, as set by a reference analytical model. Then, full 3D analyses of the nanoelectrodes’ array system are performed in order to estimate a number of relevant parameters for measurements in electrolyte. Furthermore, moving to more challenging test cases, size/permittivity of microparticles suspended in electrolyte will also be discussed. This methodology allows for the determination of impedance spectroscopy data parameters, and quantification of parameter uncertainties in these multi-variable detection problems. It is thus a very promising approach in order to improve the precision of biosensor measurement predictions, which are intrinsically affected by many parameters.File | Dimensione | Formato | |
---|---|---|---|
Calibration, Compensation, Parameter Estimation, and Uncertainty Quantification for Nanoelectrode Array Biosensors.pdf
non disponibili
Tipologia:
Abstract
Licenza:
Non pubblico
Dimensione
113.39 kB
Formato
Adobe PDF
|
113.39 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.