OBJECTIVES To evaluate the results of aortic valve replacement through sternotomic approach in redo scenarios (RAVR) vs transapical transcatheter aortic valve replacement (TAVR), in patients in the eighth decade of life or older already undergone previous coronary artery bypass grafting (CABG). METHODS One hundred and twenty-six patients undergoing RAVR were compared with 113 patients undergoing TaTAVR in terms of 30-day mortality and Valve Academic Research Consortium-2 outcomes. The two groups were also analysed after propensity-matching. RESULTS TaTAVR patients demonstrated a higher incidence of 30-day mortality (P = 0.03), stroke (P = 0.04), major bleeding (P = 0.03), worse 'early safety' (P = 0.04) and lower permanent pacemaker implantation (P = 0.03). TaTAVR had higher follow-up hazard in all-cause mortality [hazard ratio (HR) 3.15, 95% confidence interval (CI) 1.28-6.62; P < 0.01] and cardiovascular mortality (HR 1.66, 95% CI 1.02-4.88; P = 0.04). Propensity-matched patients showed comparable 30-day outcome in terms of survival, major morbidity and early safety, with only a lower incidence of transfusions after TaTAVR (10.7% vs RAVR: 57.1%; P < 0.01). A trend towards lower Acute Kidney Injury Network Classification 2/3 (3.6% vs RAVR 21.4%; P = 0.05) and towards a lower freedom from all-cause mortality at follow-up (TaTAVR: 44.3 ± 21.3% vs RAVR: 86.6 ± 9.3%; P =. 08) was demonstrated after TaTAVR, although cardiovascular mortality was comparable (TaTAVR: 86.5 ± 9.7% vs RAVR: 95.2 ± 4.6%; P = 0.52). Follow-up freedom from stroke, acute heart failure, reintervention on AVR and thrombo-embolisms were comparable (P = NS). EuroSCORE II (P = 0.02), perioperative stroke (P = 0.01) and length of hospitalization (P = 0.02) were the determinants of all-cause mortality at follow-up, whereas perioperative stroke (P = 0.03) and length of hospitalization (P = 0.04) impacted cardiovascular mortality at follow-up. CONCLUSIONS Reported differences in mortality and morbidity after TaTAVR and RAVR reflect differences in baseline risk profiles. Given the lower trend for renal complications, patients at higher perioperative renal risk might be better served by TaTAVR.

Results of surgical aortic valve replacement and transapical transcatheter aortic valve replacement in patients with previous coronary artery bypass grafting

LIVI, Ugolino;
2016-01-01

Abstract

OBJECTIVES To evaluate the results of aortic valve replacement through sternotomic approach in redo scenarios (RAVR) vs transapical transcatheter aortic valve replacement (TAVR), in patients in the eighth decade of life or older already undergone previous coronary artery bypass grafting (CABG). METHODS One hundred and twenty-six patients undergoing RAVR were compared with 113 patients undergoing TaTAVR in terms of 30-day mortality and Valve Academic Research Consortium-2 outcomes. The two groups were also analysed after propensity-matching. RESULTS TaTAVR patients demonstrated a higher incidence of 30-day mortality (P = 0.03), stroke (P = 0.04), major bleeding (P = 0.03), worse 'early safety' (P = 0.04) and lower permanent pacemaker implantation (P = 0.03). TaTAVR had higher follow-up hazard in all-cause mortality [hazard ratio (HR) 3.15, 95% confidence interval (CI) 1.28-6.62; P < 0.01] and cardiovascular mortality (HR 1.66, 95% CI 1.02-4.88; P = 0.04). Propensity-matched patients showed comparable 30-day outcome in terms of survival, major morbidity and early safety, with only a lower incidence of transfusions after TaTAVR (10.7% vs RAVR: 57.1%; P < 0.01). A trend towards lower Acute Kidney Injury Network Classification 2/3 (3.6% vs RAVR 21.4%; P = 0.05) and towards a lower freedom from all-cause mortality at follow-up (TaTAVR: 44.3 ± 21.3% vs RAVR: 86.6 ± 9.3%; P =. 08) was demonstrated after TaTAVR, although cardiovascular mortality was comparable (TaTAVR: 86.5 ± 9.7% vs RAVR: 95.2 ± 4.6%; P = 0.52). Follow-up freedom from stroke, acute heart failure, reintervention on AVR and thrombo-embolisms were comparable (P = NS). EuroSCORE II (P = 0.02), perioperative stroke (P = 0.01) and length of hospitalization (P = 0.02) were the determinants of all-cause mortality at follow-up, whereas perioperative stroke (P = 0.03) and length of hospitalization (P = 0.04) impacted cardiovascular mortality at follow-up. CONCLUSIONS Reported differences in mortality and morbidity after TaTAVR and RAVR reflect differences in baseline risk profiles. Given the lower trend for renal complications, patients at higher perioperative renal risk might be better served by TaTAVR.
File in questo prodotto:
File Dimensione Formato  
onorati2016.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Non pubblico
Dimensione 240.86 kB
Formato Adobe PDF
240.86 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1086449
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 17
social impact