Purpose Reduction of noise of breath-by-breath gas-exchange data is crucial to improve measurements. A recently described algorithm (" independent breath"), that neglects the contiguity in time of breaths, was tested. Methods Oxygen, carbon dioxide fractions, and ventilatory flow were recorded continuously over 26 min in 20 healthy volunteers at rest, during unloaded and moderate intensity cycling and subsequent recovery; oxygen uptake (.V O 2) was calculated with the " independent breath" algorithm (IND) and, for comparison, with three other " classical" algorithms. Average.V O 2 and standard deviations were calculated for steady-state conditions; non-linear regression was run throughout the.V O 2 data of the transient phases (ON and OFF), using a mono-exponential function. Results Comparisons of the different algorithms showed that they yielded similar average.V O 2 at steady state (p = NS). The standard deviations were significantly lower for IND (post hoc contrasts, p < 0.001), with the slope of the relationship with the corresponding data obtained from " classical" algorithms being < 0.69. For both transients, the overall kinetics (evaluated as time delay + time constant) was significantly faster for IND (post hoc contrasts, p < 0.001). For the ON transient, the asymptotic standard errors of the kinetic parameters were significantly lower for IND, with the slope of the regression line with the corresponding values obtained from the " classical" algorithms being < 0.60. Conclusion The " independent breath" algorithm provided consistent average -O2 uptake values while reducing the overall noise of about 30%, which might result in the halving of the required number of repeated trials needed to assess the kinetic parameters of the ON transient.

The “independent breath” algorithm: assessment of oxygen uptake during exercise

Francescato, Maria Pia
;
2019-01-01

Abstract

Purpose Reduction of noise of breath-by-breath gas-exchange data is crucial to improve measurements. A recently described algorithm (" independent breath"), that neglects the contiguity in time of breaths, was tested. Methods Oxygen, carbon dioxide fractions, and ventilatory flow were recorded continuously over 26 min in 20 healthy volunteers at rest, during unloaded and moderate intensity cycling and subsequent recovery; oxygen uptake (.V O 2) was calculated with the " independent breath" algorithm (IND) and, for comparison, with three other " classical" algorithms. Average.V O 2 and standard deviations were calculated for steady-state conditions; non-linear regression was run throughout the.V O 2 data of the transient phases (ON and OFF), using a mono-exponential function. Results Comparisons of the different algorithms showed that they yielded similar average.V O 2 at steady state (p = NS). The standard deviations were significantly lower for IND (post hoc contrasts, p < 0.001), with the slope of the relationship with the corresponding data obtained from " classical" algorithms being < 0.69. For both transients, the overall kinetics (evaluated as time delay + time constant) was significantly faster for IND (post hoc contrasts, p < 0.001). For the ON transient, the asymptotic standard errors of the kinetic parameters were significantly lower for IND, with the slope of the regression line with the corresponding values obtained from the " classical" algorithms being < 0.60. Conclusion The " independent breath" algorithm provided consistent average -O2 uptake values while reducing the overall noise of about 30%, which might result in the halving of the required number of repeated trials needed to assess the kinetic parameters of the ON transient.
File in questo prodotto:
File Dimensione Formato  
2019_EJAP.pdf

non disponibili

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Non pubblico
Dimensione 3.54 MB
Formato Adobe PDF
3.54 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1148186
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact