The accuracy of quantitative measurements represents an essential pre-requisite to the characterization and definition of the complex dynamic phenomena occurring in the field of cell biology. In research projects that involve the induction of blood coagulation under flow in microfluidic artificial channels, thrombus volume is an important quantity for estimation as a significant index related to the individual thrombotic risk profile. Concerning its importance in the early diagnosis of cardiovascular diseases, the estimated thrombus volume should reflect and represent reality. In 3D confocal microscopy, systematic errors can arise from distortions of the axial distance, whose accurate calibration remains a challenge. As a result, the 3D reconstructions show a noticeable axial elongation, and the volume measurements are thus overestimated. In this paper, a 400-600 % volume overestimation is demonstrated, and a new easy to use and automatic calibration procedure is outlined for this specific microfluidic and optical context. The adaptive algorithm proposed leads to the automatic compensation of the elongation error and to the accurate thrombus volume measurement. The method has been calibrated using fluorescent beads of known volume, validated with groups of several distinct platelets and finally applied on platelet thrombi.

A new method for accurate platelet thrombi volume measurement using a confocal microscope

De Zanet, Denise
Investigation
;
Battiston, Monica
Validation
;
Specogna, Ruben
Writing – Review & Editing
;
Trevisan, Francesco
Writing – Review & Editing
;
Affanni, Antonio
Conceptualization
;
2019-01-01

Abstract

The accuracy of quantitative measurements represents an essential pre-requisite to the characterization and definition of the complex dynamic phenomena occurring in the field of cell biology. In research projects that involve the induction of blood coagulation under flow in microfluidic artificial channels, thrombus volume is an important quantity for estimation as a significant index related to the individual thrombotic risk profile. Concerning its importance in the early diagnosis of cardiovascular diseases, the estimated thrombus volume should reflect and represent reality. In 3D confocal microscopy, systematic errors can arise from distortions of the axial distance, whose accurate calibration remains a challenge. As a result, the 3D reconstructions show a noticeable axial elongation, and the volume measurements are thus overestimated. In this paper, a 400-600 % volume overestimation is demonstrated, and a new easy to use and automatic calibration procedure is outlined for this specific microfluidic and optical context. The adaptive algorithm proposed leads to the automatic compensation of the elongation error and to the accurate thrombus volume measurement. The method has been calibrated using fluorescent beads of known volume, validated with groups of several distinct platelets and finally applied on platelet thrombi.
File in questo prodotto:
File Dimensione Formato  
547-4683-1-PB.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 754.41 kB
Formato Adobe PDF
754.41 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1148807
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact