Rainfall-runoff models must be calibrated and validated before they can be used for urban stormwater management. Manual calibration is very difficult and time-consuming due to the large number of model parameters that must be estimated concurrently. Automatic calibration offers as a promising alternative, ideally supporting a user-independent and time-efficient approach to model parameters estimation. In this article, we test the use of a state-of-the-art standard package (PEST, Parameter ESTimation, http://www.pesthomepage.org/) for the automatic calibration of a rainfall-runoff EPA-SWMM (Storm Water Management Model) model developed for a small suburban catchment. Results reported in the paper demonstrate that the performance of automatically calibrated models still depends on a number of user-dependent choices (the level of catchment discretization, the selection of significant parameters, the optimization techniques adopted). Through a systematic analysis of the results, we try to identify the guidelines for the effective use of automatic calibration procedures based on modeling assumptions and target of the analysis.

Automated calibration of the EPA-SWMM model for a small suburban catchment using PEST: a case study

Perin R.
;
Nicolini M.;Campolo M.;Goi D.
2020-01-01

Abstract

Rainfall-runoff models must be calibrated and validated before they can be used for urban stormwater management. Manual calibration is very difficult and time-consuming due to the large number of model parameters that must be estimated concurrently. Automatic calibration offers as a promising alternative, ideally supporting a user-independent and time-efficient approach to model parameters estimation. In this article, we test the use of a state-of-the-art standard package (PEST, Parameter ESTimation, http://www.pesthomepage.org/) for the automatic calibration of a rainfall-runoff EPA-SWMM (Storm Water Management Model) model developed for a small suburban catchment. Results reported in the paper demonstrate that the performance of automatically calibrated models still depends on a number of user-dependent choices (the level of catchment discretization, the selection of significant parameters, the optimization techniques adopted). Through a systematic analysis of the results, we try to identify the guidelines for the effective use of automatic calibration procedures based on modeling assumptions and target of the analysis.
File in questo prodotto:
File Dimensione Formato  
Perin2020_Article_AutomatedCalibrationOfTheEPA-S.pdf

accesso aperto

Descrizione: articolo
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.32 MB
Formato Adobe PDF
2.32 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1186893
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 28
social impact