Dedicated Mechanical Subcooling (DMS) is one of the most investigated and effective strategies applied to increase the performance of CO2 commercial refrigeration systems in transcritical operation. Further performance benefits can be obtained by a reduction of the gas cooler pressure of the main cycle at transcritical conditions. In this work the most important parameters for the design and operation of such a system, i.e. the DMS cooling capacity, the subcooling degree and the gas cooler pressure, are considered and their effect on the annual energy use of the plant is estimated in warm and hot climate conditions by means of a validated model. DMS is also compared to the parallel compression scheme and subcooling performed through a water chiller dedicated to HVAC. DMS results to be the most effective solution among those investigated, and the choice of the best design and operating parameters allows further energy saving and cost reduction.

Effect of dedicated mechanical subcooler size and gas cooler pressure control on transcritical CO2 booster systems

D'Agaro, P.;Cortella, G.
2020-01-01

Abstract

Dedicated Mechanical Subcooling (DMS) is one of the most investigated and effective strategies applied to increase the performance of CO2 commercial refrigeration systems in transcritical operation. Further performance benefits can be obtained by a reduction of the gas cooler pressure of the main cycle at transcritical conditions. In this work the most important parameters for the design and operation of such a system, i.e. the DMS cooling capacity, the subcooling degree and the gas cooler pressure, are considered and their effect on the annual energy use of the plant is estimated in warm and hot climate conditions by means of a validated model. DMS is also compared to the parallel compression scheme and subcooling performed through a water chiller dedicated to HVAC. DMS results to be the most effective solution among those investigated, and the choice of the best design and operating parameters allows further energy saving and cost reduction.
File in questo prodotto:
File Dimensione Formato  
Optimized DMS_for IRIS.pdf

accesso aperto

Tipologia: Documento in Pre-print
Licenza: Creative commons
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF Visualizza/Apri
rj41.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Non pubblico
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1191089
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact