To compare the detection of the SARS-CoV-2 Omicron variant in nasopharyngeal-swab (NPS) and oral saliva samples. 255 samples were obtained from 85 Omicron-infected patients. SARS-CoV-2 load was measured in the NPS and saliva samples by using Simplexa™ COVID-19 direct and Alinity m SARS-CoV-2 AMP assays. Results obtained with the two diagnostic platforms showed very good inter-assay concordance (91.4 and 82.4% for saliva and NPS samples, respectively) and a significant correlation among cycle threshold (Ct) values. Both platforms revealed a highly significant correlation among Ct obtained in the two matrices. Although the median Ct value was lower in NPS than in saliva samples, the Ct drop was comparable in size for both types of samples after 7 days of antiviral treatment of the Omicron-infected patients. Our result demonstrates that the detection of the SARS-CoV-2 Omicron variant is not influenced by the type of sample used for PCR analysis, and that saliva can be used as an alternative specimen for detection and follow-up of Omicron-infected patients.
Comparison of SARS-CoV-2 Detection in Nasopharyngeal Swab and Saliva Samples from Patients Infected with Omicron Variant
Lanini S.;
2023-01-01
Abstract
To compare the detection of the SARS-CoV-2 Omicron variant in nasopharyngeal-swab (NPS) and oral saliva samples. 255 samples were obtained from 85 Omicron-infected patients. SARS-CoV-2 load was measured in the NPS and saliva samples by using Simplexa™ COVID-19 direct and Alinity m SARS-CoV-2 AMP assays. Results obtained with the two diagnostic platforms showed very good inter-assay concordance (91.4 and 82.4% for saliva and NPS samples, respectively) and a significant correlation among cycle threshold (Ct) values. Both platforms revealed a highly significant correlation among Ct obtained in the two matrices. Although the median Ct value was lower in NPS than in saliva samples, the Ct drop was comparable in size for both types of samples after 7 days of antiviral treatment of the Omicron-infected patients. Our result demonstrates that the detection of the SARS-CoV-2 Omicron variant is not influenced by the type of sample used for PCR analysis, and that saliva can be used as an alternative specimen for detection and follow-up of Omicron-infected patients.File | Dimensione | Formato | |
---|---|---|---|
ijms-24-04847.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
960.72 kB
Formato
Adobe PDF
|
960.72 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.