The roomtemperature ionic liquid trihexyl(tetradecyl)phosphoniumdecanoate ([P66614][Dec]) was employed in the liquid-liquid extraction of Co(II) from hydrochloric acid solutions in the presence of Ni(II). The extraction performance in liquid-liquid separations showed a strong dependence on the acid content of the feed aqueous solution. The best performance in terms of extracted cobalt and selectivity was obtained when the feed contained a HCl concentration above 6 M On the contrary, when the experiment was performed in absence of HCl, a lower extraction and Co/Ni electivity were obtained. This behavior has been rationalized by considering the protonation of the [Dec]− anion and the different Co(II)/Ni(II) speciation in HCl media. Moreover, polymer inclusion membranes (PIMs) were prepared using PVC and [P66614][Dec] at different weight rations. Only the PIM formulated with a 30:70/PVC:[P66614][Dec] weight ratio demonstrated effective extraction of Co(II) from the HCl solution. The extraction efficiency and selectivity of the PIM was comparable to that from biphasic liquid experiments at 8 M HCl. The results of this study constitute a promising background for further practical developments of carboxylate-based ILs applied in Co/Ni separations.

Selective Co(II) and Ni(II) Separation Using the Trihexyl(tetradecyl)phosphonium Decanoate Ionic Liquid

Andela Kovacevic;Marilena Tolazzi;Andrea Melchior;Martina Sanadar
2024-01-01

Abstract

The roomtemperature ionic liquid trihexyl(tetradecyl)phosphoniumdecanoate ([P66614][Dec]) was employed in the liquid-liquid extraction of Co(II) from hydrochloric acid solutions in the presence of Ni(II). The extraction performance in liquid-liquid separations showed a strong dependence on the acid content of the feed aqueous solution. The best performance in terms of extracted cobalt and selectivity was obtained when the feed contained a HCl concentration above 6 M On the contrary, when the experiment was performed in absence of HCl, a lower extraction and Co/Ni electivity were obtained. This behavior has been rationalized by considering the protonation of the [Dec]− anion and the different Co(II)/Ni(II) speciation in HCl media. Moreover, polymer inclusion membranes (PIMs) were prepared using PVC and [P66614][Dec] at different weight rations. Only the PIM formulated with a 30:70/PVC:[P66614][Dec] weight ratio demonstrated effective extraction of Co(II) from the HCl solution. The extraction efficiency and selectivity of the PIM was comparable to that from biphasic liquid experiments at 8 M HCl. The results of this study constitute a promising background for further practical developments of carboxylate-based ILs applied in Co/Ni separations.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1292369
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact