The roomtemperature ionic liquid trihexyl(tetradecyl)phosphoniumdecanoate ([P66614][Dec]) was employed in the liquid-liquid extraction of Co(II) from hydrochloric acid solutions in the presence of Ni(II). The extraction performance in liquid-liquid separations showed a strong dependence on the acid content of the feed aqueous solution. The best performance in terms of extracted cobalt and selectivity was obtained when the feed contained a HCl concentration above 6 M On the contrary, when the experiment was performed in absence of HCl, a lower extraction and Co/Ni electivity were obtained. This behavior has been rationalized by considering the protonation of the [Dec]− anion and the different Co(II)/Ni(II) speciation in HCl media. Moreover, polymer inclusion membranes (PIMs) were prepared using PVC and [P66614][Dec] at different weight rations. Only the PIM formulated with a 30:70/PVC:[P66614][Dec] weight ratio demonstrated effective extraction of Co(II) from the HCl solution. The extraction efficiency and selectivity of the PIM was comparable to that from biphasic liquid experiments at 8 M HCl. The results of this study constitute a promising background for further practical developments of carboxylate-based ILs applied in Co/Ni separations.
Selective Co(II) and Ni(II) Separation Using the Trihexyl(tetradecyl)phosphonium Decanoate Ionic Liquid
Andela Kovacevic;Marilena Tolazzi;Andrea Melchior
;
2024-01-01
Abstract
The roomtemperature ionic liquid trihexyl(tetradecyl)phosphoniumdecanoate ([P66614][Dec]) was employed in the liquid-liquid extraction of Co(II) from hydrochloric acid solutions in the presence of Ni(II). The extraction performance in liquid-liquid separations showed a strong dependence on the acid content of the feed aqueous solution. The best performance in terms of extracted cobalt and selectivity was obtained when the feed contained a HCl concentration above 6 M On the contrary, when the experiment was performed in absence of HCl, a lower extraction and Co/Ni electivity were obtained. This behavior has been rationalized by considering the protonation of the [Dec]− anion and the different Co(II)/Ni(II) speciation in HCl media. Moreover, polymer inclusion membranes (PIMs) were prepared using PVC and [P66614][Dec] at different weight rations. Only the PIM formulated with a 30:70/PVC:[P66614][Dec] weight ratio demonstrated effective extraction of Co(II) from the HCl solution. The extraction efficiency and selectivity of the PIM was comparable to that from biphasic liquid experiments at 8 M HCl. The results of this study constitute a promising background for further practical developments of carboxylate-based ILs applied in Co/Ni separations.File | Dimensione | Formato | |
---|---|---|---|
molecules-29-04545.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
5.6 MB
Formato
Adobe PDF
|
5.6 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.