Background/aims-Selective laser trabeculoplasty targets the pigmented trabecular meshwork cells without damage to the trabecular meshwork architecture in vitro. A study was conducted in vivo of eight eyes with uncontrolled open angle glaucoma to ascertain the immediate intraocular response to selective laser trabeculoplasty. Methods-The trabecular meshwork of each eye was treated 360 degrees with a frequency doubled Q-switched Nd:YAG laser. Intraocular pressure was measured 1, 2, 24 hours and 1, 4, 6 weeks after treatment. Results-The average preoperative intraocular pressure was 26.6 (SD 7) mm Hg (range 18-37). Two hours and 6 weeks respectively after selective trabeculoplasty intraocular pressure was reduced in all the eyes treated with an average fall of 10.6 (5.2) mm Hg or 39.9%. A pressure spike of 10 mm Hg verified in one eye 1 hour after treatment. Conclusions-Selective laser trabeculoplasty decreased intraocular pressure by an amount similar to that achieved with standard trabeculoplasty. Additional study is needed to determine whether the beneficial effect is sustained over a longer period of follow up.

Immediate intraocular pressure response to selective laser trabeculoplasty

LANZETTA, Paolo;
1999-01-01

Abstract

Background/aims-Selective laser trabeculoplasty targets the pigmented trabecular meshwork cells without damage to the trabecular meshwork architecture in vitro. A study was conducted in vivo of eight eyes with uncontrolled open angle glaucoma to ascertain the immediate intraocular response to selective laser trabeculoplasty. Methods-The trabecular meshwork of each eye was treated 360 degrees with a frequency doubled Q-switched Nd:YAG laser. Intraocular pressure was measured 1, 2, 24 hours and 1, 4, 6 weeks after treatment. Results-The average preoperative intraocular pressure was 26.6 (SD 7) mm Hg (range 18-37). Two hours and 6 weeks respectively after selective trabeculoplasty intraocular pressure was reduced in all the eyes treated with an average fall of 10.6 (5.2) mm Hg or 39.9%. A pressure spike of 10 mm Hg verified in one eye 1 hour after treatment. Conclusions-Selective laser trabeculoplasty decreased intraocular pressure by an amount similar to that achieved with standard trabeculoplasty. Additional study is needed to determine whether the beneficial effect is sustained over a longer period of follow up.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/685194
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 53
social impact