Objective. Seven-year clinical and hemodynamic results of the Cryolife O'Brien (CLOB) stentless bioprosthesis in elderly patients are reported. Methods. From 1993 to 2000, 36 patients aged >75 years had a CLOB implanted in the aortic position. Eighteen (50%) were male. All patients were monitored with serial echocardiograms performed preoperatively, at discharge, six months, one year and yearly thereafter. Results. The 30-day mortality was 2.4% (1/36). Actuarial survival at one, five and seven years were 96.7+/-1.5, 94.8+/-2.0 and 94.8+/-2.0%, respectively. Peak and mean gradients (PG and MG) reduced and effective orifice area index (EOAI) increased over time (P<0.001). Left ventricular mass index (LVMI) reduced by 32 g/m(2) at discharge (P<0.001) and by 33 g/m(2) at six months (P<0.001) without further significant changes. Conclusions, In our series CLOB xenograft resulted to be a satisfactory valve substitute in elderly patients. (C) 2002 The International Society for Cardiovascular Surgery.

Stentless aortic valve replacement in elderly patients

LIVI, Ugolino
2002-01-01

Abstract

Objective. Seven-year clinical and hemodynamic results of the Cryolife O'Brien (CLOB) stentless bioprosthesis in elderly patients are reported. Methods. From 1993 to 2000, 36 patients aged >75 years had a CLOB implanted in the aortic position. Eighteen (50%) were male. All patients were monitored with serial echocardiograms performed preoperatively, at discharge, six months, one year and yearly thereafter. Results. The 30-day mortality was 2.4% (1/36). Actuarial survival at one, five and seven years were 96.7+/-1.5, 94.8+/-2.0 and 94.8+/-2.0%, respectively. Peak and mean gradients (PG and MG) reduced and effective orifice area index (EOAI) increased over time (P<0.001). Left ventricular mass index (LVMI) reduced by 32 g/m(2) at discharge (P<0.001) and by 33 g/m(2) at six months (P<0.001) without further significant changes. Conclusions, In our series CLOB xenograft resulted to be a satisfactory valve substitute in elderly patients. (C) 2002 The International Society for Cardiovascular Surgery.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/687830
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact