Abstract Objectives: The purpose of this paper is to report long-term results on the use of autologous bone graft and platelet-rich plasma in alveolar distraction osteogenesis (DO) for restoration of severe atrophic mandible. We tested the efficacy as to reabsorption of bone volume, peri-implant reabsorption, implant survival and success rate. Materials and methods: Twelve patients were treated. The surgical procedure consisted in mixing autologous bone, harvested from the iliac crest, with autologous platelet concentrate (APC) and in filling the distraction gap with this graft. After a latency of 15 days, a distraction rate of 0.5 mm/day was followed. After a 60-day period of consolidation, the distraction device was removed and implants were placed simultaneously. The abutment connection was accomplished after 6 months. In addition, every patient was evaluated clinically and radiographically annually for 5 years. Results: Planned alveolar height was reached in 11 out of 12 patients. The total number of implants positioned was 47. At the time of implant positioning, the mean decrease of total bone volume was 2.3%. The mean peri-implant resorption was 0.40mm at the time of abutment connection, 0.61mm 1 year after implant loading and 1.51mm after 5 years. After 5 years of follow-up, the mean rate of vertical bone loss was 18.7%. Instead, the implant survival and success rates were 97.9% and 91.5%, respectively. Conclusions: Long-term results allow us to confirm the combination of autologous boneplatelet gel with alveolar DO as an effective and predictable procedure in restoration of severe atrophic mandible.

Osteogenesis distraction and platelet-rich plasma: combined use in restoration of severe atrophic mandible. Long-term results

ROBIONY, Massimo;Sembronio S;POLITI, Massimo
2008-01-01

Abstract

Abstract Objectives: The purpose of this paper is to report long-term results on the use of autologous bone graft and platelet-rich plasma in alveolar distraction osteogenesis (DO) for restoration of severe atrophic mandible. We tested the efficacy as to reabsorption of bone volume, peri-implant reabsorption, implant survival and success rate. Materials and methods: Twelve patients were treated. The surgical procedure consisted in mixing autologous bone, harvested from the iliac crest, with autologous platelet concentrate (APC) and in filling the distraction gap with this graft. After a latency of 15 days, a distraction rate of 0.5 mm/day was followed. After a 60-day period of consolidation, the distraction device was removed and implants were placed simultaneously. The abutment connection was accomplished after 6 months. In addition, every patient was evaluated clinically and radiographically annually for 5 years. Results: Planned alveolar height was reached in 11 out of 12 patients. The total number of implants positioned was 47. At the time of implant positioning, the mean decrease of total bone volume was 2.3%. The mean peri-implant resorption was 0.40mm at the time of abutment connection, 0.61mm 1 year after implant loading and 1.51mm after 5 years. After 5 years of follow-up, the mean rate of vertical bone loss was 18.7%. Instead, the implant survival and success rates were 97.9% and 91.5%, respectively. Conclusions: Long-term results allow us to confirm the combination of autologous boneplatelet gel with alveolar DO as an effective and predictable procedure in restoration of severe atrophic mandible.
File in questo prodotto:
File Dimensione Formato  
oral implant res.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 857.01 kB
Formato Adobe PDF
857.01 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/695175
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 21
social impact