Purpose of the review An adequate cardiac preload is essential in the treatment of critically ill patients. During anesthesia for thoracic surgery, volume and vasoactive therapy to optimize cardiac output, oxygen delivery (tissue perfusion) and to avoid pulmonary edema is a central therapeutic aspect. Cardiac preload has been estimated with different techniques in clinical practice, even though studies performed on thoracic anesthesia are lacking. Recent findings We analyze the conventional pulmonary artery catheter, transesophageal echocardiography and the transpulmonary indicator dilution technique as preload monitoring devices with their indications and limits in thoracic anesthesia. Summary The pulmonary artery catheter is confirmed as a fundamental device particularly in patients with pulmonary hypertension. For transesophageal echocardiography monitoring, the dependency on operator experience, the low repeatability and the high costs limit its interpretation and diffusion in clinical practice. During lung transplantation, Swan Ganz catheter monitoring is recommended. The optimization of fluid balance and vasoactive drug administration based on volumetric monitoring makes the transpulmonary indicator dilution technique a new option as an effective monitoring system during anesthesia for thoracic surgery when intravascular volume management is a primary objective.

Preload indexes in thoracic anesthesia

DELLA ROCCA, Giorgio;COSTA, Maria Gabriella
2003-01-01

Abstract

Purpose of the review An adequate cardiac preload is essential in the treatment of critically ill patients. During anesthesia for thoracic surgery, volume and vasoactive therapy to optimize cardiac output, oxygen delivery (tissue perfusion) and to avoid pulmonary edema is a central therapeutic aspect. Cardiac preload has been estimated with different techniques in clinical practice, even though studies performed on thoracic anesthesia are lacking. Recent findings We analyze the conventional pulmonary artery catheter, transesophageal echocardiography and the transpulmonary indicator dilution technique as preload monitoring devices with their indications and limits in thoracic anesthesia. Summary The pulmonary artery catheter is confirmed as a fundamental device particularly in patients with pulmonary hypertension. For transesophageal echocardiography monitoring, the dependency on operator experience, the low repeatability and the high costs limit its interpretation and diffusion in clinical practice. During lung transplantation, Swan Ganz catheter monitoring is recommended. The optimization of fluid balance and vasoactive drug administration based on volumetric monitoring makes the transpulmonary indicator dilution technique a new option as an effective monitoring system during anesthesia for thoracic surgery when intravascular volume management is a primary objective.
File in questo prodotto:
File Dimensione Formato  
Della Rocca Costa Preload in toracic aneth Curr Op Anesth 2003.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 77.92 kB
Formato Adobe PDF
77.92 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Della Rocca Costa Curr Op Anesth 2003.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 77.92 kB
Formato Adobe PDF
77.92 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Della Rocca Costa Curr Op Anesth 2003.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 77.92 kB
Formato Adobe PDF
77.92 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/710241
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact