Purpose: The PiCCO System is a relatively new device allowing intermittent cardiac output monitoring by aortic transpulmonary thermodilution technique (Aorta intermittent) and continuous car- diac output monitoring by pulse contour analysis (Aorta continu- ous). The objective of this study was to assess the level of agreement of Aorta intermittent and Aorta continuous with inter- mittent (PA intermittent) and continuous cardiac output (PA contin- uous) measured through a special pulmonary artery catheter (Vigilance System SvO2/CCO Monitor) in patients undergoing sin- gle- or double-lung transplantation. Methods: Measurements were obtained in 58 patients: at four time points in patients undergoing single-lung transplantation and at six time points in those undergoing double-lung transplantation. Bland and Altman and correlation analyses were used for statistical evaluation. Results: We found close agreement between the techniques. Mean bias between Aorta intermittent and PA intermittent and between Aorta continuous and PA continuous was 0.18 L·min–1 (2SD of differences between methods = 1.59 L·min–1) and -0.07 L·min–1 (2SD of differences between methods = 1.46 L·min–1) respectively. Mean bias between PA continuous and PA intermittent and Aorta continuous and PA intermittent was 0.15 L·min–1 (2SD of differences between methods = 1.39 L·min–1) and 0.08 L·min–1 (2SD of differences between methods = 1.43 L·min–1). Conclusion: Measurements with the aortic transpulmonary ther- modilution technique give continuous and intermittent values that agree with the pulmonary thermodilution method which is still the current clinical standard.

Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation.

DELLA ROCCA, Giorgio;COSTA, Maria Gabriella;
2003-01-01

Abstract

Purpose: The PiCCO System is a relatively new device allowing intermittent cardiac output monitoring by aortic transpulmonary thermodilution technique (Aorta intermittent) and continuous car- diac output monitoring by pulse contour analysis (Aorta continu- ous). The objective of this study was to assess the level of agreement of Aorta intermittent and Aorta continuous with inter- mittent (PA intermittent) and continuous cardiac output (PA contin- uous) measured through a special pulmonary artery catheter (Vigilance System SvO2/CCO Monitor) in patients undergoing sin- gle- or double-lung transplantation. Methods: Measurements were obtained in 58 patients: at four time points in patients undergoing single-lung transplantation and at six time points in those undergoing double-lung transplantation. Bland and Altman and correlation analyses were used for statistical evaluation. Results: We found close agreement between the techniques. Mean bias between Aorta intermittent and PA intermittent and between Aorta continuous and PA continuous was 0.18 L·min–1 (2SD of differences between methods = 1.59 L·min–1) and -0.07 L·min–1 (2SD of differences between methods = 1.46 L·min–1) respectively. Mean bias between PA continuous and PA intermittent and Aorta continuous and PA intermittent was 0.15 L·min–1 (2SD of differences between methods = 1.39 L·min–1) and 0.08 L·min–1 (2SD of differences between methods = 1.43 L·min–1). Conclusion: Measurements with the aortic transpulmonary ther- modilution technique give continuous and intermittent values that agree with the pulmonary thermodilution method which is still the current clinical standard.
File in questo prodotto:
File Dimensione Formato  
Della Rocca PCCO Canadian.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 79.11 kB
Formato Adobe PDF
79.11 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Della Rocca Costa CJA 2003.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 117.69 kB
Formato Adobe PDF
117.69 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Della Rocca PCCO Canadian.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 79.11 kB
Formato Adobe PDF
79.11 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Della Rocca PCCO Canadian.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 79.11 kB
Formato Adobe PDF
79.11 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/715061
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 107
  • ???jsp.display-item.citation.isi??? 90
social impact