This study compares the use of six different post-gadolinium T1-weighted sequences on intracranial tumours with the aim of evaluating their efficacy in terms of lesion and edema contrast resolution and cortex visualization. Forty-eight intracranial neoplastic lesions were evaluated after contrast media administration by means of the following T1-weighted sequences: Fast Spin-Echo (FSE), Spin-Echo (SE) and Gradient-Echo (GE) with and without Magnetization Transfer (MT) pulse. For each technique tumour/background contrast resolution (T/B CR), oedema/background contrast resolution (E/B CR) and white matter/grey matter contrast resolution (WM/GM CR) were calculated. GE sequences, with and without MT, showed the lowest contrast resolution values for all parameters. FSE MT sequences showed the highest T/B CR values. SE sequences, instead, showed the best E/B and WM/GM CR values. FSE and SE MT values were intermediate between FSE MT and SE sequences. No sequence had high values for all contrast resolution parameters. The sequence with the best T/B CR was the FSE MT, but that with the best anatomic peritumoural edema and cortex definition was SE. Both FSE MT and SE T1-weighted sequences may be acquired to obtain accurate post-gadolinium tumour evaluation.

Post-gadolinium evaluation of intracranial tumours: a comparative study of Spin Echo, Fast Spin Echo, Gradient Echo T1-weighted sequences, with and without Magnetization Transfer.

SCOTT, Cathryn Anne;BELTRAMI, Carlo Alberto;
2001-01-01

Abstract

This study compares the use of six different post-gadolinium T1-weighted sequences on intracranial tumours with the aim of evaluating their efficacy in terms of lesion and edema contrast resolution and cortex visualization. Forty-eight intracranial neoplastic lesions were evaluated after contrast media administration by means of the following T1-weighted sequences: Fast Spin-Echo (FSE), Spin-Echo (SE) and Gradient-Echo (GE) with and without Magnetization Transfer (MT) pulse. For each technique tumour/background contrast resolution (T/B CR), oedema/background contrast resolution (E/B CR) and white matter/grey matter contrast resolution (WM/GM CR) were calculated. GE sequences, with and without MT, showed the lowest contrast resolution values for all parameters. FSE MT sequences showed the highest T/B CR values. SE sequences, instead, showed the best E/B and WM/GM CR values. FSE and SE MT values were intermediate between FSE MT and SE sequences. No sequence had high values for all contrast resolution parameters. The sequence with the best T/B CR was the FSE MT, but that with the best anatomic peritumoural edema and cortex definition was SE. Both FSE MT and SE T1-weighted sequences may be acquired to obtain accurate post-gadolinium tumour evaluation.
File in questo prodotto:
File Dimensione Formato  
gadolinium.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 3.72 MB
Formato Adobe PDF
3.72 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/716058
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact