This paper investigates power line communication (PLC) in digitally controlled high-frequency switched-mode power supplies in distributed architectures that share the same bus voltage. Communication between different DC-DC converters is obtained by using switching frequency modulation and by detecting the switching signal on the common supply bus voltage. In case of low power transmission, a small duty-cycle perturbation at half of switching frequency is added to enhance the energy of the transmitted signal. Each converter operates at three different switching frequencies: the first is associated with bit 1 transmission, the second is associated with bit 0 transmission, and the third is associated with no transmission state. In the proposed solution, there is no need for an additional power amplifier in order to inject the communication signal on the power lines, but the signal used for the PLC is inherently generated by the pulsewidth modulation of DC-DC converters. Even if aimed at a dedicated digital IC, the communication architecture has been implemented in field-programmable gate arrays. Simulation and experimental results on DC-DC synchronous buck converters confirm that the performance is achievable by the proposed PLC techniques.

Power Line Communication in Digitally Controlled DC–DC Converters Using Switching Frequency Modulation

SAGGINI, Stefano;
2008-01-01

Abstract

This paper investigates power line communication (PLC) in digitally controlled high-frequency switched-mode power supplies in distributed architectures that share the same bus voltage. Communication between different DC-DC converters is obtained by using switching frequency modulation and by detecting the switching signal on the common supply bus voltage. In case of low power transmission, a small duty-cycle perturbation at half of switching frequency is added to enhance the energy of the transmitted signal. Each converter operates at three different switching frequencies: the first is associated with bit 1 transmission, the second is associated with bit 0 transmission, and the third is associated with no transmission state. In the proposed solution, there is no need for an additional power amplifier in order to inject the communication signal on the power lines, but the signal used for the PLC is inherently generated by the pulsewidth modulation of DC-DC converters. Even if aimed at a dedicated digital IC, the communication architecture has been implemented in field-programmable gate arrays. Simulation and experimental results on DC-DC synchronous buck converters confirm that the performance is achievable by the proposed PLC techniques.
File in questo prodotto:
File Dimensione Formato  
04441353.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 943.01 kB
Formato Adobe PDF
943.01 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/851690
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 78
  • ???jsp.display-item.citation.isi??? 60
social impact