The paper presents an optimization model of a distributed cogeneration system with a district heating network, applied to a real city centre situation. The distributed urban cogeneration system includes both a set of micro-gas turbines, located inside some public buildings, and a centralized cogeneration system based on a Internal Combustion Engine. The objective function adopted for the optimization is the Total Annual Cost for owning, maintaining and operating the whole system. To face the problem a Mixed Integer Linear Program (MILP) is defined and solved by a commercial software. Starting from the thermal and electrical demand of the buildings, the MILP model allows to define the possible installation of the centralized cogeneration ICE and the number of micro-turbines in the different buildings, the optimal lay-out of the district heating network and the optimal operation strategy for the whole system as well. In particular the energy performance and global CO2 emissions are evaluated.
Optimal lay-out and operation of combined heat & power (CHP) distributed generation system
CASISI, Melchiorre;PINAMONTI, Piero;
2009-01-01
Abstract
The paper presents an optimization model of a distributed cogeneration system with a district heating network, applied to a real city centre situation. The distributed urban cogeneration system includes both a set of micro-gas turbines, located inside some public buildings, and a centralized cogeneration system based on a Internal Combustion Engine. The objective function adopted for the optimization is the Total Annual Cost for owning, maintaining and operating the whole system. To face the problem a Mixed Integer Linear Program (MILP) is defined and solved by a commercial software. Starting from the thermal and electrical demand of the buildings, the MILP model allows to define the possible installation of the centralized cogeneration ICE and the number of micro-turbines in the different buildings, the optimal lay-out of the district heating network and the optimal operation strategy for the whole system as well. In particular the energy performance and global CO2 emissions are evaluated.File | Dimensione | Formato | |
---|---|---|---|
Pinamonti_1.pdf
non disponibili
Tipologia:
Altro materiale allegato
Licenza:
Non pubblico
Dimensione
990.86 kB
Formato
Adobe PDF
|
990.86 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.