Control units comprising a proof-mass electrodynamic actuator and accelerometer-sensor pair with a time integrator and fixed gain controller are an effective way to implement velocity feedback control on thin flexible structures. These control units produce active damping provided the fundamental resonance frequency of the actuators is well below that of the structure under control. Control stability limits arise from the actuators fundamental resonances which introduce a 180° phase lag in the sensoractuator frequency response functions, thus causing the feedback loops to be only conditionally stable. In contrast to previous studies, this paper discusses the response of a control unit with electrodynamic proof-mass actuator in terms of the open- and closed-loop base impedance that it exerts on the structure. This allows for a straight-forward physical interpretation of both stability and control performance. Experimental and simulation results show that the base impedance can be described as the sum of passive and active frequency response functions, where the active part of the control unit response depends on the actuator electromechanical response and also on the response function of the analogue controller circuit. The results show that the base impedance formulation can be effectively used to investigate new designs of both the actuator and electronic controller in order to optimise the stability and performance properties of the control unit.

Base impedance of velocity feedback control units with proof-mass electrodynamic actuators

GARDONIO, Paolo;
2011-01-01

Abstract

Control units comprising a proof-mass electrodynamic actuator and accelerometer-sensor pair with a time integrator and fixed gain controller are an effective way to implement velocity feedback control on thin flexible structures. These control units produce active damping provided the fundamental resonance frequency of the actuators is well below that of the structure under control. Control stability limits arise from the actuators fundamental resonances which introduce a 180° phase lag in the sensoractuator frequency response functions, thus causing the feedback loops to be only conditionally stable. In contrast to previous studies, this paper discusses the response of a control unit with electrodynamic proof-mass actuator in terms of the open- and closed-loop base impedance that it exerts on the structure. This allows for a straight-forward physical interpretation of both stability and control performance. Experimental and simulation results show that the base impedance can be described as the sum of passive and active frequency response functions, where the active part of the control unit response depends on the actuator electromechanical response and also on the response function of the analogue controller circuit. The results show that the base impedance formulation can be effectively used to investigate new designs of both the actuator and electronic controller in order to optimise the stability and performance properties of the control unit.
File in questo prodotto:
File Dimensione Formato  
JSV_2011_Rohlfing_Elliott_Gardonio.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Non pubblico
Dimensione 1.85 MB
Formato Adobe PDF
1.85 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/866640
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 32
social impact