Non-destructive dynamic methods are a useful tool in structural engineering. Their purpose is twofold. On the one hand, they provide a guidance on the validation of a mathematical model of the structure under investigation. On the other hand, repeated tests over time can indicate the emergence of possible damage occurring during the structure's lifetime. Recent technological progress has generated extremely accurate and reliable experimental methods, enabling a good estimate of dynamic behavior of a structural system. Although experimental techniques are now well-established, the interpretation of measurements still lags somewhat behind. This particularly concerns structural identification due to its nature of inverse problem. In addition, when identification techniques are applied to the study of real-world structures, additional obstacles arise given the complexity of the structural behavior, the inaccuracy of the analytical models used to interpret experiments, measurement errors and incomplete field data. In this research we discuss some of these aspects with reference to a series of harmonic forced vibration tests carried out on the new headquarters of the Hypo Bank (Tavagnacco, North-East Italy). The special structural typology of tilted building and the complex distribution of the resisting structural members have made interesting, and at the same time quite complicated, the interpretation of the real dynamic behavior of the construction. The present paper (Part I) is devoted to the experimental programme. The use of the measured dynamic data in the calibration of numerical models of the Hypo Bank complex is presented and discussed in the next paper (Part II).

Dynamic testing and structural identification of the Hypo Bank Office complex. Part I: Experiments

MORASSI, Antonino
2011-01-01

Abstract

Non-destructive dynamic methods are a useful tool in structural engineering. Their purpose is twofold. On the one hand, they provide a guidance on the validation of a mathematical model of the structure under investigation. On the other hand, repeated tests over time can indicate the emergence of possible damage occurring during the structure's lifetime. Recent technological progress has generated extremely accurate and reliable experimental methods, enabling a good estimate of dynamic behavior of a structural system. Although experimental techniques are now well-established, the interpretation of measurements still lags somewhat behind. This particularly concerns structural identification due to its nature of inverse problem. In addition, when identification techniques are applied to the study of real-world structures, additional obstacles arise given the complexity of the structural behavior, the inaccuracy of the analytical models used to interpret experiments, measurement errors and incomplete field data. In this research we discuss some of these aspects with reference to a series of harmonic forced vibration tests carried out on the new headquarters of the Hypo Bank (Tavagnacco, North-East Italy). The special structural typology of tilted building and the complex distribution of the resisting structural members have made interesting, and at the same time quite complicated, the interpretation of the real dynamic behavior of the construction. The present paper (Part I) is devoted to the experimental programme. The use of the measured dynamic data in the calibration of numerical models of the Hypo Bank complex is presented and discussed in the next paper (Part II).
File in questo prodotto:
File Dimensione Formato  
Morassi_JSE_ASCE_137(12)_2011_pp1527-1539.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 1.92 MB
Formato Adobe PDF
1.92 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/869241
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact