Objective: To compare the usefulness of 3D power Doppler angiography (3D-PDA) and endometrial thickness measurement by 2D Doppler ultrasound in the distinction of benign from malignant disease in postmenopausal women with abnormal uterine bleeding (AUB) and an endometrial thickness greater than 4.5 mm. Methods: Forty-eight women with AUB and an endometrial thickness greater than 4.5 mm on 2D ultrasound underwent 3D-PDA. The endometrium and a 5-mm subendometrial shell were evaluated at rotation angles of 9° and 30°. Endometrial volume, vascularity index, flow index, and vascularization flow index were obtained. Results: The histologic findings were normal or benign for 38 women (79%) and malignant for 10 (21%). All vascular indices were significantly higher in the group with malignancies except for the vascularization flow index. There were no differences in the values obtained using the 9° or the 30° angle. Receiver-operating characteristics curves were traced for all indices. The vascularity index had the best area under the curve (0.78), 77.8% sensitivity, and 82.6% specificity. The areas under the curve were smaller for the shell than for the endometrium. Conclusion: 3D-PDA was not found better than 2D ultrasound at distinguishing benign from malignant disease in women with AUB and an endometrial thickness greater than 4.5 mm.

Assessment of endometrial volume and vascularization using transvaginal 3D power Doppler angiography in women with postmenopausal bleeding.

ROSSI, Alberto;FORZANO, Leonardo;ROMANELLO, Irene;FACHECHI, Giorgio;MARCHESONI, Diego
2012-01-01

Abstract

Objective: To compare the usefulness of 3D power Doppler angiography (3D-PDA) and endometrial thickness measurement by 2D Doppler ultrasound in the distinction of benign from malignant disease in postmenopausal women with abnormal uterine bleeding (AUB) and an endometrial thickness greater than 4.5 mm. Methods: Forty-eight women with AUB and an endometrial thickness greater than 4.5 mm on 2D ultrasound underwent 3D-PDA. The endometrium and a 5-mm subendometrial shell were evaluated at rotation angles of 9° and 30°. Endometrial volume, vascularity index, flow index, and vascularization flow index were obtained. Results: The histologic findings were normal or benign for 38 women (79%) and malignant for 10 (21%). All vascular indices were significantly higher in the group with malignancies except for the vascularization flow index. There were no differences in the values obtained using the 9° or the 30° angle. Receiver-operating characteristics curves were traced for all indices. The vascularity index had the best area under the curve (0.78), 77.8% sensitivity, and 82.6% specificity. The areas under the curve were smaller for the shell than for the endometrium. Conclusion: 3D-PDA was not found better than 2D ultrasound at distinguishing benign from malignant disease in women with AUB and an endometrial thickness greater than 4.5 mm.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/872282
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact