The behaviour of pulmonary O2 uptake following a moderate-intensity step exercise increment is usually described by a first brief increase, followed by a second exponential time course reaching the new steady state (phase II). The parameters describing the phase II kinetics are investigated by applying different data treatments to the acquired O2 uptake data to reduce the effects of their noise before running a non-linear regression procedure. The effects of different data treatments (nothing, resampling at various time intervals or averaging of more repetitions) on the precision and/or accuracy of the kinetics parameters estimated by non-linear regression with a simple mono-exponential model were investigated by artificially generating 105 simulated responses with average breath duration of 3.5 s. The simulations showed that, whatever the explored data treatment, the average estimated parameters were close to the theoretical ones. Nevertheless, in all the explored conditions, the non-linear regression provided narrower asymptotic confidence intervals than the real ones. In particular, when the responses were resampled at 1 s time intervals, the width of the asymptotic confidence interval for the time constant was 50% of the real one, even after the averaging of more repetitions. The reasons for this discrepancy were investigated further, allowing us to identify some methods to obtain the correct confidence interval of the O2 uptake kinetics parameters. The simplest method to obtain an asymptotic confidence interval close to the real one is to average more responses resampled to a time interval slightly longer than the average breath duration

Confidence Intervals of the parameters estimated from simulated O2 uptake kinetics: effects of different data treatments.

FRANCESCATO, Maria Pia;BELLIO, Ruggero
2014-01-01

Abstract

The behaviour of pulmonary O2 uptake following a moderate-intensity step exercise increment is usually described by a first brief increase, followed by a second exponential time course reaching the new steady state (phase II). The parameters describing the phase II kinetics are investigated by applying different data treatments to the acquired O2 uptake data to reduce the effects of their noise before running a non-linear regression procedure. The effects of different data treatments (nothing, resampling at various time intervals or averaging of more repetitions) on the precision and/or accuracy of the kinetics parameters estimated by non-linear regression with a simple mono-exponential model were investigated by artificially generating 105 simulated responses with average breath duration of 3.5 s. The simulations showed that, whatever the explored data treatment, the average estimated parameters were close to the theoretical ones. Nevertheless, in all the explored conditions, the non-linear regression provided narrower asymptotic confidence intervals than the real ones. In particular, when the responses were resampled at 1 s time intervals, the width of the asymptotic confidence interval for the time constant was 50% of the real one, even after the averaging of more repetitions. The reasons for this discrepancy were investigated further, allowing us to identify some methods to obtain the correct confidence interval of the O2 uptake kinetics parameters. The simplest method to obtain an asymptotic confidence interval close to the real one is to average more responses resampled to a time interval slightly longer than the average breath duration
File in questo prodotto:
File Dimensione Formato  
2014_ExpPhysiol.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 471.1 kB
Formato Adobe PDF
471.1 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/876198
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 21
social impact