Background: At present the interest in medical field about the generation of three-dimensional digital models of anatomical structures increases due to the widespread diffusion of CAS - computer assisted surgery - systems. Most of them are based on CT computer tomography - or MR - magnetic resonance - data volumes but sometimes this information is not available; there are only few X-ray, ultrasound or fluoroscopic images. Methods: This paper describes the study and the development of a script for a commercial software package (ads Max) able to reconfigure the template model of a femur starting from two orthogonal images representing the specific patient's anatomy. Results: The script was used in several tests as summarized in this paper and the results appear to be interesting and acceptable, even for the medical experts that evaluated them. Conclusions: The script developed in this work allows the generation of the 3D model of a femur in a very simple way (the user interface has been developed obeying to the main usability guidelines) and using a widespread commercial package. The quality of the results can be compared to the quality of more expensive and specialized systems. (c) 2007 Elsevier Ireland Ltd. All rights reserved. RI Motyl, Barbara/B-1193-2010; Filippi, Stefano/A-6118-2009

Analysis of Existing Methods for 3D Modelling of Femurs starting from Two Orthogonal Images and Development of a Script for a Commercial Software Package

FILIPPI, Stefano;MOTYL, Barbara;BANDERA, Camillo
2008-01-01

Abstract

Background: At present the interest in medical field about the generation of three-dimensional digital models of anatomical structures increases due to the widespread diffusion of CAS - computer assisted surgery - systems. Most of them are based on CT computer tomography - or MR - magnetic resonance - data volumes but sometimes this information is not available; there are only few X-ray, ultrasound or fluoroscopic images. Methods: This paper describes the study and the development of a script for a commercial software package (ads Max) able to reconfigure the template model of a femur starting from two orthogonal images representing the specific patient's anatomy. Results: The script was used in several tests as summarized in this paper and the results appear to be interesting and acceptable, even for the medical experts that evaluated them. Conclusions: The script developed in this work allows the generation of the 3D model of a femur in a very simple way (the user interface has been developed obeying to the main usability guidelines) and using a widespread commercial package. The quality of the results can be compared to the quality of more expensive and specialized systems. (c) 2007 Elsevier Ireland Ltd. All rights reserved. RI Motyl, Barbara/B-1193-2010; Filippi, Stefano/A-6118-2009
File in questo prodotto:
File Dimensione Formato  
2008-CMPB_Analysis of existing methods for 3D modelling of femurs.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Analysis of existing methods for 3D modeling Filippi.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/877451
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 32
social impact