Background: Patients with diabetes are recommended to self-monitor their blood glucose levels also at home. Accuracy of a hand-held glucometer and a Continuous Glucose Monitoring (CGM) device were comparatively evaluated. Methods: Venous blood samples (for reference laboratory determinations; n = 428) were collected from 18 type 1 patients (35-65 years old), immediately followed by capillary measurement (Bayer ContourLink meter) and CGM readings (Medtronic Paradigm). Results: Laboratory values did not differ statistically from ContourLink and CGM readings, mean difference (+/- SD) being -0.05 +/- 1.06 mmol/L and 0.10 +/- 1.84 mmol/L glucose, respectively. A bias ((value - reference)/reference x 100) >= 15% was observed in 27.7% and 54.9% of cases, respectively. Notably, below 3.9 mmol/L glucose (hypoglycemic threshold), an absolute error > 0.8 mmol/L was found in 78.9% and 94.1% of cases. The absolute errors of the CGM device were inversely related to the rate of glucose change (r = 0.598, p<0.001). Conclusions: A very large error was observed at the extreme glycemic values, which may lead to erroneous therapy. Consequently, performance of future portable glucometers should be focused in particular under hypo- and hyperglycemia. Moreover, integrated CGM devices should not disregard the effect of the rate of blood glucose change on the sensor readings. (C) 2011 Elsevier By. All rights reserved. Clin Chim Acta. 2012 Jan 18;413(1-2):312-8. Epub 2011 Oct 18. Accuracy of a portable glucose meter
Accuracy of a portable glucose meter and of a continuous glucose monitoring device used at home by patients with type 1 diabetes
FRANCESCATO, Maria Pia;STEL, Giuliana;CAUCI, Sabina
2012-01-01
Abstract
Background: Patients with diabetes are recommended to self-monitor their blood glucose levels also at home. Accuracy of a hand-held glucometer and a Continuous Glucose Monitoring (CGM) device were comparatively evaluated. Methods: Venous blood samples (for reference laboratory determinations; n = 428) were collected from 18 type 1 patients (35-65 years old), immediately followed by capillary measurement (Bayer ContourLink meter) and CGM readings (Medtronic Paradigm). Results: Laboratory values did not differ statistically from ContourLink and CGM readings, mean difference (+/- SD) being -0.05 +/- 1.06 mmol/L and 0.10 +/- 1.84 mmol/L glucose, respectively. A bias ((value - reference)/reference x 100) >= 15% was observed in 27.7% and 54.9% of cases, respectively. Notably, below 3.9 mmol/L glucose (hypoglycemic threshold), an absolute error > 0.8 mmol/L was found in 78.9% and 94.1% of cases. The absolute errors of the CGM device were inversely related to the rate of glucose change (r = 0.598, p<0.001). Conclusions: A very large error was observed at the extreme glycemic values, which may lead to erroneous therapy. Consequently, performance of future portable glucometers should be focused in particular under hypo- and hyperglycemia. Moreover, integrated CGM devices should not disregard the effect of the rate of blood glucose change on the sensor readings. (C) 2011 Elsevier By. All rights reserved. Clin Chim Acta. 2012 Jan 18;413(1-2):312-8. Epub 2011 Oct 18. Accuracy of a portable glucose meterFile | Dimensione | Formato | |
---|---|---|---|
Francescato.Cauci.2012.pdf
non disponibili
Tipologia:
Altro materiale allegato
Licenza:
Non pubblico
Dimensione
657.68 kB
Formato
Adobe PDF
|
657.68 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.