PURPOSE: The purpose of this study was to assess the accuracy and clinical usefulness of stereotactic vacuum-assisted biopsy (VAB) for diagnosing suspicious, nonpalpable, only mammographically detectable breast lesions. MATERIALS AND METHODS: We retrospectively evaluated the results of percutaneous stereotactic VAB with 11-gauge needles performed over a period of 34 months on 228 nonpalpable suspicious breast lesions detectable on mammography only [Breast Imaging Reporting and Data System (BI-RADS) 3: 25.9%; BI-RADS 4: 67.1%; BI-RADS 5: 7%]. The imaging histological concordance was ascertained for each lesion. In cases of discordance, repeat biopsy or surgical excision were recommended; in cases of benign lesions, we urged a follow-up of at least 6 months and for borderline and malignant lesions a surgical excision. We also evaluated concordance between VAB results and subsequent examinations (surgical excision or followup). RESULTS: VAB demonstrated 123 (54%) benign lesions (with six cases of imaging-histological discordance), 26 (11.4%) borderline lesions and 79 (34.6%) malignant lesions. We obtained a suitable post-VAB mammographic or histological evaluation for 78 benign lesions, 17 borderline lesions and 76 malignant lesions, with one (1.3%) false negative (FN) case, two (11.8%) underestimations of borderline lesions, 14 (18.4%) underestimations of malignant lesions and no (0%) false positive cases. We did not observe any postbiopsy complications or scars. CONCLUSIONS: Percutaneous histological VAB with an 11-gauge needle proved to be, as reported in previous studies, a reliable method for diagnosing nonpalpable, mammographically detectable only breast lesions, with an underestimation rate lower than core biopsy and a FN rate similar to that of surgical biopsy, without any significant complications.

Stereotactic vacuum-assisted breast biopsy: results, follow-up and correlation with radiological suspicion

ZUIANI, Chiara;PUGLISI, Fabio;BAZZOCCHI, Massimo
2007-01-01

Abstract

PURPOSE: The purpose of this study was to assess the accuracy and clinical usefulness of stereotactic vacuum-assisted biopsy (VAB) for diagnosing suspicious, nonpalpable, only mammographically detectable breast lesions. MATERIALS AND METHODS: We retrospectively evaluated the results of percutaneous stereotactic VAB with 11-gauge needles performed over a period of 34 months on 228 nonpalpable suspicious breast lesions detectable on mammography only [Breast Imaging Reporting and Data System (BI-RADS) 3: 25.9%; BI-RADS 4: 67.1%; BI-RADS 5: 7%]. The imaging histological concordance was ascertained for each lesion. In cases of discordance, repeat biopsy or surgical excision were recommended; in cases of benign lesions, we urged a follow-up of at least 6 months and for borderline and malignant lesions a surgical excision. We also evaluated concordance between VAB results and subsequent examinations (surgical excision or followup). RESULTS: VAB demonstrated 123 (54%) benign lesions (with six cases of imaging-histological discordance), 26 (11.4%) borderline lesions and 79 (34.6%) malignant lesions. We obtained a suitable post-VAB mammographic or histological evaluation for 78 benign lesions, 17 borderline lesions and 76 malignant lesions, with one (1.3%) false negative (FN) case, two (11.8%) underestimations of borderline lesions, 14 (18.4%) underestimations of malignant lesions and no (0%) false positive cases. We did not observe any postbiopsy complications or scars. CONCLUSIONS: Percutaneous histological VAB with an 11-gauge needle proved to be, as reported in previous studies, a reliable method for diagnosing nonpalpable, mammographically detectable only breast lesions, with an underestimation rate lower than core biopsy and a FN rate similar to that of surgical biopsy, without any significant complications.
File in questo prodotto:
File Dimensione Formato  
Zuiani et al__Puglisi__Radiol Med 2007.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 117.78 kB
Formato Adobe PDF
117.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
load_page.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 117.78 kB
Formato Adobe PDF
117.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/879910
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 17
social impact