A conveniently assembled membrane-free amperometric sensor is proposed for the detection of oxygen in gaseous atmospheres which exploits some profitable properties of room temperature ionic liquids (RTILs), such as their high electrical conductivity, negligible vapour pressure and good thermal stability. The advantages offered by this type of medium were increased by adding small amounts of a further low melting salt bearing a quinone moiety, which allowed the reduction of O-2 to occur through an electrocatalytic pathway taking place at quite lower potentials than those required by its direct reduction. The rate constant (14,160 +/- 370 M-1 s(-1)) of this electrocatalytic process was determined by resorting to linear sweep voltammetric measurements. The performance of this device was assayed under both flowing and static stop-flow conditions on synthetic O-2 + N-2 atmospheres with a controlled oxygen content, which was changed in a wide range (200-10(6) ppm v/v). At room temperature, repeatable (+/- 2.7%) and linearly dependent current signals were recorded, allowing a detection limit of 140 ppm v/v (equivalent to 6.2 x 10(-6) mol of O-2 per L of gaseous atmosphere) to be inferred. At higher temperatures (100 degrees C) a lower detection limit (10 ppm v/v, equivalent to 4.5 x 10(-7) mol of O-2 per L of gaseous atmosphere) could be instead estimated. The possibility of profiting from this sensor for monitoring oxygen under reduced pressure was also assayed, in view of the growing importance attached to the evaluation of residual O-2 in food packaging under vacuum or controlled atmospheres. (C) 2012 Elsevier B.V. All rights reserved.

An oxygen amperometric gas sensor based on its electrocatalytic reduction in room temperature ionic liquid

TONIOLO, Rosanna;DOSSI, Nicolo';SUSMEL, Sabina;BONTEMPELLI, Gino
2012-01-01

Abstract

A conveniently assembled membrane-free amperometric sensor is proposed for the detection of oxygen in gaseous atmospheres which exploits some profitable properties of room temperature ionic liquids (RTILs), such as their high electrical conductivity, negligible vapour pressure and good thermal stability. The advantages offered by this type of medium were increased by adding small amounts of a further low melting salt bearing a quinone moiety, which allowed the reduction of O-2 to occur through an electrocatalytic pathway taking place at quite lower potentials than those required by its direct reduction. The rate constant (14,160 +/- 370 M-1 s(-1)) of this electrocatalytic process was determined by resorting to linear sweep voltammetric measurements. The performance of this device was assayed under both flowing and static stop-flow conditions on synthetic O-2 + N-2 atmospheres with a controlled oxygen content, which was changed in a wide range (200-10(6) ppm v/v). At room temperature, repeatable (+/- 2.7%) and linearly dependent current signals were recorded, allowing a detection limit of 140 ppm v/v (equivalent to 6.2 x 10(-6) mol of O-2 per L of gaseous atmosphere) to be inferred. At higher temperatures (100 degrees C) a lower detection limit (10 ppm v/v, equivalent to 4.5 x 10(-7) mol of O-2 per L of gaseous atmosphere) could be instead estimated. The possibility of profiting from this sensor for monitoring oxygen under reduced pressure was also assayed, in view of the growing importance attached to the evaluation of residual O-2 in food packaging under vacuum or controlled atmospheres. (C) 2012 Elsevier B.V. All rights reserved.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1572665712000562-2012_01.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Non pubblico
Dimensione 443.55 kB
Formato Adobe PDF
443.55 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/881162
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 35
social impact