Purpose of review To highlight the recent developments in hemodynamic monitoring during liver and lung transplantation. Recent findings Even though a consensus on intraoperative hemodynamic monitoring is still lacking, the most frequently monitoring tool used is the pulmonary artery catheter (PAC). The filling pressures are widely accepted as not being able to accurately define cardiac preload. On the contrary, the use of transesophageal echocardiography (TEE), although it is operator dependent and requires a prolonged training, is increasing during the intraoperative period to directly evaluate the cardiovascular function. New frontiers have been opened by the transpulmonary thermodilution: intrathoracic blood volume has been shown to have a better correlation with preload than the filling pressures. The advanced modified PAC permits evaluation of the right heart function and preload. Recently, right ventricular end diastolic volume has been shown to correlate better with preload than the filling pressures and also the left ventricular end diastolic area. Summary The PAC still represents the most used intraoperative hemodynamic monitoring technique. TEE is increasing in popularity. Recent studies demonstrate that volumetric monitoring conducted with transpulmonary thermodilution and advanced volumetric PAC give good definition of preload and should be implemented in clinical practice.

Intraoperative hemodynamic monitoring during organ transplantation: what is new?

DELLA ROCCA, Giorgio;COSTA, Maria Gabriella
2009-01-01

Abstract

Purpose of review To highlight the recent developments in hemodynamic monitoring during liver and lung transplantation. Recent findings Even though a consensus on intraoperative hemodynamic monitoring is still lacking, the most frequently monitoring tool used is the pulmonary artery catheter (PAC). The filling pressures are widely accepted as not being able to accurately define cardiac preload. On the contrary, the use of transesophageal echocardiography (TEE), although it is operator dependent and requires a prolonged training, is increasing during the intraoperative period to directly evaluate the cardiovascular function. New frontiers have been opened by the transpulmonary thermodilution: intrathoracic blood volume has been shown to have a better correlation with preload than the filling pressures. The advanced modified PAC permits evaluation of the right heart function and preload. Recently, right ventricular end diastolic volume has been shown to correlate better with preload than the filling pressures and also the left ventricular end diastolic area. Summary The PAC still represents the most used intraoperative hemodynamic monitoring technique. TEE is increasing in popularity. Recent studies demonstrate that volumetric monitoring conducted with transpulmonary thermodilution and advanced volumetric PAC give good definition of preload and should be implemented in clinical practice.
File in questo prodotto:
File Dimensione Formato  
GDR Curr Opin Organ TX 2009.pdf

non disponibili

Tipologia: Altro materiale allegato
Licenza: Non pubblico
Dimensione 103.78 kB
Formato Adobe PDF
103.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/881471
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 31
social impact