The use of hemp (Cannabis sativa L.) essential oil (EO) has shown a significant increase in interest and use during recent years. In this work, a new and simple reversed-phase HPLC with photodiode-array (PDA) detector method has been developed and optimized for the detection and quantification of cannabidiolic acid (CBDA), cannabidiol (CBD), cannabinol (CBN), Δ9-tetrahydrocannabinol (Δ9-THC), and Δ9-tetrahydrocannabinolic acid (THCA). The cannabinoids were extracted from the EO by partition with n-hexane and water, followed by sonication, evaporation to dryness under nitrogen, and reconstitution with methanol:chloroform (9:1, v/v) before HPLC-PDA analysis. The method shows good selectivity and robustness, linearity in the range 0.5–100 mg L−1 with R2 higher than 0.999 for all cannabinoids analyzed, LOD of 0.11–0.16 mg L−1, and LOQ of 0.35–0.48 mg L−1. The recovery was between 78 and 100% and the intra-day and intermediate precision, expressed as relative standard deviation (RSD), was < 4% and 4–10%, respectively.

Development and Optimization of an HPLC-PDA Method for the Determination of Major Cannabinoids in Hemp (Cannabis sativa L.) Essential Oil Obtained by Hydrodistillation

Ferfuia C.;Bortolomeazzi R.;Verardo G.;Baldini M.
2022-01-01

Abstract

The use of hemp (Cannabis sativa L.) essential oil (EO) has shown a significant increase in interest and use during recent years. In this work, a new and simple reversed-phase HPLC with photodiode-array (PDA) detector method has been developed and optimized for the detection and quantification of cannabidiolic acid (CBDA), cannabidiol (CBD), cannabinol (CBN), Δ9-tetrahydrocannabinol (Δ9-THC), and Δ9-tetrahydrocannabinolic acid (THCA). The cannabinoids were extracted from the EO by partition with n-hexane and water, followed by sonication, evaporation to dryness under nitrogen, and reconstitution with methanol:chloroform (9:1, v/v) before HPLC-PDA analysis. The method shows good selectivity and robustness, linearity in the range 0.5–100 mg L−1 with R2 higher than 0.999 for all cannabinoids analyzed, LOD of 0.11–0.16 mg L−1, and LOQ of 0.35–0.48 mg L−1. The recovery was between 78 and 100% and the intra-day and intermediate precision, expressed as relative standard deviation (RSD), was < 4% and 4–10%, respectively.
File in questo prodotto:
File Dimensione Formato  
Piani2022_Article_DevelopmentAndOptimizationOfAn.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/1222764
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact