The use of hemp (Cannabis sativa L.) essential oil (EO) has shown a significant increase in interest and use during recent years. In this work, a new and simple reversed-phase HPLC with photodiode-array (PDA) detector method has been developed and optimized for the detection and quantification of cannabidiolic acid (CBDA), cannabidiol (CBD), cannabinol (CBN), Δ9-tetrahydrocannabinol (Δ9-THC), and Δ9-tetrahydrocannabinolic acid (THCA). The cannabinoids were extracted from the EO by partition with n-hexane and water, followed by sonication, evaporation to dryness under nitrogen, and reconstitution with methanol:chloroform (9:1, v/v) before HPLC-PDA analysis. The method shows good selectivity and robustness, linearity in the range 0.5–100 mg L−1 with R2 higher than 0.999 for all cannabinoids analyzed, LOD of 0.11–0.16 mg L−1, and LOQ of 0.35–0.48 mg L−1. The recovery was between 78 and 100% and the intra-day and intermediate precision, expressed as relative standard deviation (RSD), was < 4% and 4–10%, respectively.
Development and Optimization of an HPLC-PDA Method for the Determination of Major Cannabinoids in Hemp (Cannabis sativa L.) Essential Oil Obtained by Hydrodistillation
Ferfuia C.;Bortolomeazzi R.;Verardo G.;Baldini M.
2022-01-01
Abstract
The use of hemp (Cannabis sativa L.) essential oil (EO) has shown a significant increase in interest and use during recent years. In this work, a new and simple reversed-phase HPLC with photodiode-array (PDA) detector method has been developed and optimized for the detection and quantification of cannabidiolic acid (CBDA), cannabidiol (CBD), cannabinol (CBN), Δ9-tetrahydrocannabinol (Δ9-THC), and Δ9-tetrahydrocannabinolic acid (THCA). The cannabinoids were extracted from the EO by partition with n-hexane and water, followed by sonication, evaporation to dryness under nitrogen, and reconstitution with methanol:chloroform (9:1, v/v) before HPLC-PDA analysis. The method shows good selectivity and robustness, linearity in the range 0.5–100 mg L−1 with R2 higher than 0.999 for all cannabinoids analyzed, LOD of 0.11–0.16 mg L−1, and LOQ of 0.35–0.48 mg L−1. The recovery was between 78 and 100% and the intra-day and intermediate precision, expressed as relative standard deviation (RSD), was < 4% and 4–10%, respectively.File | Dimensione | Formato | |
---|---|---|---|
Piani2022_Article_DevelopmentAndOptimizationOfAn.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
1.21 MB
Formato
Adobe PDF
|
1.21 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.