This study reports on the first use of the “optothermistor” as a novel, precise, fast, and low-cost detector of lycopene in a wide range of commercially available processed-tomato products. The quantitative performance of the new device was evaluated by comparing data obtained to that acquired by conventional methods, namely, absorption spectrophotometry and high-performance liquid chromatography (HPLC); the linear correlation was high (R ) 0.98). The variation of data obtained with the optothermistor in a series of consecutive measurements performed with the same loading of the sample was better than 1%. However, the repeatability (RSD 0.5-9.0%, n ) 3-5) achieved with the optothermistor by independent analyses (multiple loading) is comparable to that of HPLC and spectrophotometry. Results of the studies performed on the 19 products derived from tomatoes demonstrated that the optothermistor is suitable for selective, accurate, precise, and simple determination of lycopene (range ) 7-75 mg/100 g of product weight) without the need for a sample pretreatment step. The estimated sensitivity of the present optothermistor is 2 mg of lycopene/100 g of product.

Optothermistor as a breakthrough in the quantification of lycopene content of thermally processed tomato-based foods: verification versus absorption spectrophotometry and high-performance liquid chromatography

ANESE, Monica
2005-01-01

Abstract

This study reports on the first use of the “optothermistor” as a novel, precise, fast, and low-cost detector of lycopene in a wide range of commercially available processed-tomato products. The quantitative performance of the new device was evaluated by comparing data obtained to that acquired by conventional methods, namely, absorption spectrophotometry and high-performance liquid chromatography (HPLC); the linear correlation was high (R ) 0.98). The variation of data obtained with the optothermistor in a series of consecutive measurements performed with the same loading of the sample was better than 1%. However, the repeatability (RSD 0.5-9.0%, n ) 3-5) achieved with the optothermistor by independent analyses (multiple loading) is comparable to that of HPLC and spectrophotometry. Results of the studies performed on the 19 products derived from tomatoes demonstrated that the optothermistor is suitable for selective, accurate, precise, and simple determination of lycopene (range ) 7-75 mg/100 g of product weight) without the need for a sample pretreatment step. The estimated sensitivity of the present optothermistor is 2 mg of lycopene/100 g of product.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11390/856287
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact