The performance of a novel rapid-scanning (20 000 amu/s) quadrupole mass spectrometer (qMS) has been evaluated in the comprehensive 2-D gas chromatography (GC×GC) analysis of pesticides contained in water. Analyte extraction was performed by using direct solid-phase microextraction (SPME). The MS system was operated using a rather wide m/z 50–450 mass range and a 33 Hz spectral production rate, a frequency which was found sufficient for reliable quantification. The qMS performance was evaluated considering: (i) number of data points per peak, (ii) mass spectral quality, (iii) extent of peak skewing, and (iv) consistency of retention times. Seven-point calibration curves (external calibration) were constructed for 28 pesticides over the limit of quantification range of 100 μg/L (1, 5, 10, 25, 50, and 100 μg/L). The solid-phase microextraction-GC×GC-qMS method was validated by calculating limits of detection and quantification, intraday peak area precision, accuracy, and intraday retention-time precision. A series of tap water samples were subjected to analysis, fortunately giving negative results.
Performance evaluaton of a rapid scanning quadrupole mass spectrometer in the comprehensive two dimensional chromatography analysis of drinking water pesticides
PURCARO, Giorgia;CONTE, Lanfranco;
2011-01-01
Abstract
The performance of a novel rapid-scanning (20 000 amu/s) quadrupole mass spectrometer (qMS) has been evaluated in the comprehensive 2-D gas chromatography (GC×GC) analysis of pesticides contained in water. Analyte extraction was performed by using direct solid-phase microextraction (SPME). The MS system was operated using a rather wide m/z 50–450 mass range and a 33 Hz spectral production rate, a frequency which was found sufficient for reliable quantification. The qMS performance was evaluated considering: (i) number of data points per peak, (ii) mass spectral quality, (iii) extent of peak skewing, and (iv) consistency of retention times. Seven-point calibration curves (external calibration) were constructed for 28 pesticides over the limit of quantification range of 100 μg/L (1, 5, 10, 25, 50, and 100 μg/L). The solid-phase microextraction-GC×GC-qMS method was validated by calculating limits of detection and quantification, intraday peak area precision, accuracy, and intraday retention-time precision. A series of tap water samples were subjected to analysis, fortunately giving negative results.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.